A4AH4 Air Handler
- All-aluminum coil
- Factory-installed flow control to support ratings
- Fully insulated galvanized steel cabinet
- Multi-speed fan motors
- Assembled in Vidalia, Georgia
A4AH4 Air Handler
A4AH4 Multi-Position Air Handler
Model | Capacity (Tons) | Motor Type | Flow Control | Electric Heat | Dimensions (in) | ||
H | W | D | |||||
A4AH4P18A1B60B | 1.5 | PSC | Orifice | Field Installed | 45.02 | 18.50 | 21.13 |
A4AH4P24A1B60B | 2 | PSC | Orifice | Field Installed | 45.02 | 18.50 | 21.13 |
A4AH4P30A1B60B | 2.5 | PSC | Orifice | Field Installed | 45.02 | 18.50 | 21.13 |
A4AH4P36A1B30B | 3 | PSC | TXV | Field Installed | 45.02 | 18.50 | 21.13 |
A4AH4P37A1C30B | 3 | PSC | TXV | Field Installed | 51.27 | 23.50 | 21.13 |
A4AH4E42A1C30B | 3.5 | CTM | TXV | Field Installed | 51.27 | 23.50 | 21.13 |
A4AH4E48A1C30B | 4 | CTM | TXV | Field Installed | 51.27 | 23.50 | 21.13 |
A4AH4E60A1C30B | 5 | CTM | TXV | Field Installed | 51.27 | 23.50 | 21.13 |
RunTru Limited Warranty:
5-year limited warranty for functional parts
10-year warranty for functional parts with registration
20-year warranty for heat exchanger
Find out more about the RunTru Limited Warranty here.
Owner Guide
Contractor Resources
Technical Documents

A4AH6 Air Handler
- All-aluminum coil
- Factory-installed flow control to support ratings
- Fully insulated galvanized steel cabinet
- Multi-speed fan motors
- Assembled in Vidalia, Georgia
A4AH6 Air Handler
A4AH6 Multi-Position Air Handler
Model | Capacity (Tons) | Motor Type | Flow Control | Electric Heat | Dimensions (in) | ||
H | W | D | |||||
A4AH6E19A1B30AA | 1.5 | TXV | Orifice | Field Installed | 45 | 18.5 | 21 |
A4AH6E31A1B30AA | 2.5 | TXV | Orifice | Field Installed | 46.8 | 18.5 | 21 |
A4AH6E43A1C30AA | 3.5 | PSC | TXV | Field Installed | 51.3 | 23.5 | 21 |
A4AH6E49A1C30AA | 4 | PSC | TXV | Field Installed | 55.9 | 23.5 | 21 |
A4AH6E61A1C30AA | 5 | PSC | TXV | Field Installed | 55.9 | 23.5 | 21 |
A4AH6V24A1B30AA | 2 | PSC | TXV | Field Installed | 46.8 | 18.5 | 21 |
A4AH6V30A1B30AA | 2.5 | PSC | TXV | Field Installed | 46.8 | 18.5 | 21 |
A4AH6V36A1C30AA | 3 | PSC | TXV | Field Installed | 51.3 | 23.5 | 21 |
A4AH6V42A1C30AA | 3.5 | PSC | TXV | Field Installed | 51.3 | 23.5 | 21 |
A4AH6V48A1D30AA | 4 | PSC | TXV | Field Installed | 55.9 | 23.5 | 21 |
A4AH6V60A1D30AA | 5 | PSC | TXV | Field Installed | 53.9 | 26.5 | 21 |
A4AH6V48A1C30AA | 4 | PSC | TXV | Field Installed | 55.9 | 23.5 | 21 |
A4AH6V60A1C30AA | 5 | PSC | TXV | Field Installed | 53.9 | 26.5 | 21 |
RunTru Limited Warranty:
5-year limited warranty for functional parts
10-year warranty for functional parts with registration
20-year warranty for heat exchanger
Find out more about the RunTru Limited Warranty here.
Owner Guide
Contractor Resources
Technical Documents

TMM4/TMM5 Air Handler
- All-aluminum coil
- Galvanized steel cabinet
- No-rust drain pan
- Small footprint for tight spaces
TMM4/TMM5 Air Handler
TMM4 Air Handlers
Model | Capacity (Tons) | Motor Type | Flow Control | Electric Heat | Dimensions (in) | ||
H | W | D | |||||
TMM4B0A18S21SA | 1.5 | ECM | Orifice | Field Installed | 36.5 | 20.5 | 15 |
TMM4B0A24S21SA | 2 | ECM | Orifice | Field Installed | 36.5 | 20.5 | 15 |
TMM4B0B30S21SA | 2.5 | ECM | Orifice | Field Installed | 39.5 | 22 | 19 |
TMM4B0B36S21SA | 3 | ECM | Orifice | Field Installed | 39.5 | 22 | 19 |
TMM5 Air Handlers
Model | Capacity (Tons) | Motor Type | Flow Control | Electric Heat | Dimensions (in) | ||
H | W | D | |||||
TMM5B0A24M21SA | 2 | ECM | TXV | Field Installed | 36.5 | 20.5 | 15 |
TMM5B0B30M21SA | 2.5 | ECM | TXV | Field Installed | 39.5 | 22 | 19 |
TMM5B0B36M21SA | 3 | ECM | TXV | Field Installed | 39.5 | 22 | 19 |
RunTru Limited Warranty:
10-year limited functional parts warranty
No registration required
Find out more about the RunTru Limited Warranty here.
Owner Guide
Contractor Resources
Technical Documents

GMU/V Air Handler
- All-aluminum coil
- Factory-installed flow control to support ratings
- Fully insulated galvanized steel cabinet
- Multi-speed fan motors
- Factory-installed electric heat with breaker
- Assembled in Vidalia, Georgia
GMU/V Air Handler
GMU/V Front Return Upflow Air Handler
Model | Capacity (Tons) | Motor Type | Flow Control | Electric Heat | Dimensions (in) | ||
H | W | D | |||||
GMU2APB24051SA | 1.5-2 | PSC | Orifice | 5kW | 25.40 | 22.10 | 19.30 |
GMU2APB24081SA | 1.5-2 | PSC | Orifice | 8kW | 25.40 | 22.10 | 19.30 |
GMU2APB30051SA | 2.5 | PSC | Orifice | 5kW | 29.40 | 22.10 | 19.30 |
GMU2APB30081SA | 2.5 | PSC | Orifice | 8kW | 29.40 | 22.10 | 19.30 |
GMU2AEB37051SA | 2.5-3 | CTM | Orifice | 5kW | 29.40 | 22.10 | 19.30 |
GMU2AEB37101SA | 2.5-3 | CTM | Orifice | 10kW | 29.40 | 22.10 | 19.30 |
GMV2APB26051SA | 1.5-2 | PSC | TXV* | 5kW | 26.00 | 22.10 | 19.30 |
GMV2APB26081SA | 1.5-2 | PSC | TXV* | 8kW | 26.00 | 22.10 | 19.30 |
GMV2APB32051SA | 2.5 | PSC | TXV* | 5kW | 29.40 | 22.10 | 19.30 |
GMV2APB32081SA | 2.5 | PSC | TXV* | 8kW | 29.40 | 22.10 | 19.30 |
GMV2AEB39051SA | 2.5-3 | CTM | TXV* | 5kW | 29.40 | 22.10 | 19.30 |
GMV2AEB39101SA | 2.5-3 | CTM | TXV* | 10kW | 29.40 | 22.10 | 19.30 |
*TXV is shipped with unit and field installed.
RunTru Limited Warranty:
5-year limited warranty for functional parts
10-year warranty for functional parts with registration
20-year warranty for heat exchanger
Find out more about the RunTru Limited Warranty here.